A broken fenestrated tracheostomy tube fragment removed from the right main bronchus
Keywords:
airway, aspiration, complication, foreign body, tracheostomy tubeAbstract
Aspiration of a broken tracheostomy tube fragment is a relatively rare complication with the potential to result in serious airway complications. Case reports of tracheal fragment aspiration have been documented infrequently in the past, with the earliest documented case in 1960. What follows is a case report of an 80-year-old male patient whose tracheostomy was replaced a year ago. While at home, the tracheostomy broke and the fragment lodged in his right main bronchus. He was unable to recall when the tracheostomy broke and only presented to the ear, nose and throat clinic for his annual follow-up appointment. The discussion highlights similar reported cases and emphasises some concerns regarding the long-term use of tracheostomies. (Full text available online at www.medpharm.tandfonline.com/ojaa) South Afr J Anaesth Analg 2016; DOI: 10.1080/22201181.2016.1244315Downloads
Additional Files
Published
2016-11-30
Issue
Section
Case Studies
License
By submitting manuscripts to SAJAA, authors of original articles are assigning copyright to the SA Society of Anaesthesiologists. Authors may use their own work after publication without written permission, provided they acknowledge the original source. Individuals and academic institutions may freely copy and distribute articles published in SAJAA for educational and research purposes without obtaining permission.